Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Ophthalmology ; 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38582155

RESUMEN

PURPOSE: To compare the effectiveness and safety of a single injection of subconjunctival triamcinolone acetonide (TA) with that of postoperative topical prednisolone acetate (PA) with and without nonsteroidal anti-inflammatory drugs (NSAIDs) for cataract surgery prophylaxis. DESIGN: Retrospective, comparative effectiveness cohort study. PARTICIPANTS: Patients at Kaiser Permanente Northern California from 2018 through 2021. INTERVENTION: Exposure groups included topical PA with or without NSAID and subconjunctival injection of TA (Kenalog; Bristol-Myers-Squibb) 10 mg/ml or 40 mg/ml in a low dose (1.0-3.0 mg) or high dose (3.1-5.0 mg). MAIN OUTCOME MEASURES: The adjusted odds ratio (OR) and 95% confidence interval (CI) for the association of postoperative macular edema (ME) and iritis diagnoses 15 to 120 days after surgery (effectiveness measures) and a glaucoma-related event (safety measure) between 15 days and 1 year after surgery. RESULTS: Of 69 832 eligible patient-eyes, postoperative ME, iritis, and a glaucoma-related event occurred on average in 1.3%, 0.8%, and 3.4% of eyes in the topical groups and 0.8%, 0.5%, and 2.8% of eyes in the injection groups, respectively. In multivariable analysis, compared with the PA reference group, the PA plus NSAID group had a lower OR of ME (OR, 0.88; 95% CI, 0.74-1.04; P = 0.135). and all injection groups had even lower odds, with the high-dose TA 10-mg/ml group reaching statistical significance (OR, 0.64; 95% CI, 0.43-0.97; P = 0.033). A trend of lower odds of a postoperative iritis diagnosis was noted in the high-strength (40 mg/ml) groups. For postoperative glaucoma-related events, compared with PA, the TA 10-mg/ml low-dose group showed lower odds (OR, 0.69; 95% CI, 0.55-0.86; P = 0.001), the TA 10-mg/ml high-dose group showed similar odds (OR, 0.90; 95% CI, 0.70-1.15; P = 0.40), and the TA 40-mg/ml low-dose and high-dose groups showed higher odds of an event occurring (OR, 1.46 [95% CI, 0.98-2.18; P = 0.062] and OR, 2.14 [95% CI, 1.36-3.37; P = 0.001], respectively). CONCLUSIONS: The TA 10-mg/ml high-dose (4 mg) group was associated with a lower risk of postoperative ME and a similar risk of glaucoma-related events compared with the topical groups. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

2.
Methods Enzymol ; 687: 87-102, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37666640

RESUMEN

Manganese is one of the essential trace elements found in erythrocytes. Metal transporters situated on the plasma membrane generally facilitate the movement of manganese into and out of cells. This study aims at determining whether two recently discovered manganese importers, ZIP8 and ZIP14, are located in the erythrocyte membrane. We outline a simple, effective and repeatable method for the isolation of erythrocyte membrane from a minimum of 50 µL mouse blood, followed by the identification of ZIP metal transporters using immunoblotting. Our results revealed that ZIP8 is expressed within the erythrocyte membrane, in contrast to ZIP14 which is not identified using immunoblotting approach. A direct measurement of the ZIP8 protein expression in erythrocyte membranes could provide valuable information for further analyzing its biological function.


Asunto(s)
Membrana Eritrocítica , Manganeso , Animales , Ratones , Eritrocitos , Metales , Immunoblotting , Proteínas de Transporte de Membrana
3.
J Biol Chem ; 299(8): 105078, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37482277

RESUMEN

Manganese (Mn) is an essential nutrient, but is toxic in excess. Whole-body Mn levels are regulated in part by the metal-ion influx transporter SLC39A8, which plays an essential role in the liver by reclaiming Mn from bile. Physiological roles of SLC39A8 in Mn homeostasis in other tissues, however, remain largely unknown. To screen for extrahepatic requirements for SLC39A8 in tissue Mn homeostasis, we crossed Slc39a8-inducible global-KO (Slc39a8 iKO) mice with Slc39a14 KO mice, which display markedly elevated blood and tissue Mn levels. Tissues were then analyzed by inductively coupled plasma-mass spectrometry to determine levels of Mn. Although Slc39a14 KO; Slc39a8 iKO mice exhibited systemic hypermanganesemia and increased Mn loading in the bone and kidney due to Slc39a14 deficiency, we show Mn loading was markedly decreased in the brains of these animals, suggesting a role for SLC39A8 in brain Mn accumulation. Levels of other divalent metals in the brain were unaffected, indicating a specific effect of SLC39A8 on Mn. In vivo radiotracer studies using 54Mn in Slc39a8 iKO mice revealed that SLC39A8 is required for Mn uptake by the brain, but not most other tissues. Furthermore, decreased 54Mn uptake in the brains of Slc39a8 iKO mice was associated with efficient inactivation of Slc39a8 in isolated brain microvessels but not in isolated choroid plexus, suggesting SLC39A8 mediates brain Mn uptake via the blood-brain barrier. These findings establish SLC39A8 as a candidate therapeutic target for mitigating Mn uptake and accumulation in the brain, the primary organ of Mn toxicity.


Asunto(s)
Encéfalo , Proteínas de Transporte de Catión , Manganeso , Animales , Ratones , Transporte Biológico , Encéfalo/metabolismo , Proteínas de Transporte de Catión/genética , Proteínas de Transporte de Catión/metabolismo , Manganeso/metabolismo , Ratones Noqueados
4.
Comput Struct Biotechnol J ; 21: 2332-2338, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37020930

RESUMEN

ZIP14 is a metal transporter essential for the regulation of body manganese homeostasis. The physiological functions of ZIP14 have been uncovered mainly through two lines of in vivo studies that examined the phenotypes of ZIP14 loss, including studies of humans with ZIP14 mutations and animals with ZIP14 deficiency. This mini review aims at presenting an updated view of the important advances made towards understanding the genetic and pathological mechanisms of brain manganese overload caused by ZIP14 deficiency.

5.
Ther Adv Ophthalmol ; 14: 25158414211070878, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35495617

RESUMEN

Biological drugs, termed biologics, are medications that contain or are derived from a living organism (human, animal, or microorganism). With new biological agents being approved by the Food and Drug Administration (FDA) every year, clinicians need to know potential ocular adverse effects that are associated with these drugs. This review provides an overview of ocular adverse effects of biological medications used to treat both ophthalmic and non-ophthalmic diseases. We searched PubMed for relevant case reports, case series, reviews, and clinical trials reporting ocular adverse effects caused by biologics. This review was conducted in June 2021 and investigated the drugs listed in the most updated (April 2021) FDA Purple Book Database of Licensed Biological Products. This review focuses on monoclonal antibodies, interleukins, and receptor fusion proteins. We explore ocular side effects of 33 biological drugs, stating whether they are frequent, common, or rare.

6.
Expert Rev Med Devices ; 19(4): 375-383, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35582877

RESUMEN

OBJECTIVES: To assess the repeatability and reproducibility of corneal measurements performed by the Galilei G6 and determine its agreement with the Pentacam® AXL. METHODS: 105 eyes underwent examination by both devices, measuring nine parameters. Paired t-tests, Deming Regression, and Bland-Altman plots were used to determine agreement. Analysis of Variance was used to determine repeatability and reproducibility. RESULTS: Measurements showed no clinically significant differences between the two devices. On average, the Galilei G6 measured axial length longer than the Pentacam® AXL by 0.05 mm ± 0.03 mm (p < 0.001), just 0.2% of the mean value and therefore clinically insignificant. It measured central corneal thickness and anterior chamber depth 3.77 µm ± 7.71 µm longer (p < 0.001) and 0.04 mm ± 0.07 µm shorter (p < 0.001), respectively. They are also clinically insignificant, constituting just 0.7% and 1% of the mean values. The results showed evidence of repeatability and reproducibility. Only measurements of corneal cylinder showed some clinically significant variance. CONCLUSIONS: The Galilei G6 and Pentacam® AXL measurements show evidence of repeatability, reproducibility, and agreement for examined parameters. Certain caution needs to be applied in cases with moderate or severe corneal cylinder, due to discrepancies in repeatability and reproducibility of corneal cylinder measurements with the Galilei G6.


Asunto(s)
Córnea , Tomografía Computarizada por Rayos X , Biometría , Córnea/diagnóstico por imagen , Paquimetría Corneal , Topografía de la Córnea , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica
7.
Eye Contact Lens ; 48(6): 232-238, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35301272

RESUMEN

ABSTRACT: Thygeson superficial punctate keratitis (TSPK) is clinically characterized by exacerbations and remissions of gray-white opacities within the corneal epithelium, most often bilateral but may be asymmetric. Symptoms typically include photophobia, tearing, blurring, and eye irritation. Although disease progression and prognosis are well described, the exact cause is unknown. Hypotheses exist implicating virus-mediated immunity as the cause of TSPK following cases of viral keratitis; however, several polymerase chain reaction studies refute the infectious process concurrently with symptomatic TSPK. This is further supported by the consistent lack of response to antiviral and antibacterial treatment. A subset of dendritic cells known as Langerhans cells (LC) found within the corneal epithelium has been positively correlated with exacerbations of TSPK. Langerhans cells proliferate to protect and mitigate the cornea's inflammatory response, but the inflammatory triggers and relapses associated with TSPK are not well understood. Several topical drugs exist to treat inflammation related to TSPK; however, drug delivery is a major barrier to treatment because of the tear film and epithelial barrier. Drug-eluting contact lenses that target intermediates of inflammation could serve as a more effective treatment modality because of the increased bioavailability of the drugs. This review is an in-depth survey of the literature regarding the relationship between the origin and pathophysiology of LC and TSPK at the immunologic level. We also discuss potential pharmacotherapeutic interventions for TSPK prevention and treatment.


Asunto(s)
Opacidad de la Córnea , Epitelio Corneal , Infecciones Virales del Ojo , Queratitis , Opacidad de la Córnea/etiología , Infecciones Virales del Ojo/complicaciones , Humanos , Inflamación , Queratitis/tratamiento farmacológico , Queratitis/terapia
8.
J Refract Surg ; 38(2): 106-111, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35156462

RESUMEN

PURPOSE: To assess the efficacy of different devices and nomograms in predicting the most optimal Implantable Collamer Lens (ICL) (STAAR Surgical) size. METHODS: This retrospective study includes 73 patients (142 eyes) who underwent ICL placement surgery. Anterior segment measurements were obtained by the OPD-Scan III (Marco), the Lenstar LS 900 (Haag-Streit AG/Alcon Laboratories, Inc), the Galilei G4 (Ziemer), and the VuMax ultrasound biomicroscopy device (UBM) (Sonomed Escalon). The efficacy of the four devices and four nomograms was assessed by comparing the indicated ICL sizes to the patient's postoperative vault measurements. RESULTS: Using white-to-white (WTW) measurements obtained by the Lenstar LS 900 and Galilei G4 coupled with the U.S. Food and Drug Administration's (FDA) (also called the manufacturer's) nomogram predicted the highest percentage (33% and 43%) of the 13.7 mm ICL sizes, respectively. Using the VuMax UBM coupled with the Dougherty nomogram indicated the highest percentage (80%) of the 12.6 mm ICL size. The ICL sizes predicted by UBM using the Parkhurst nomogram were comparable to those deemed ideal according to postoperative vault measurements. CONCLUSIONS: The Parkhurst nomogram predicted the most appropriate ICL size. When using WTW measurements, the optimized WTW nomogram showed promising results, especially in eyes whose preoperative calculations suggest low postoperative vaults. Moreover, clinicians should use caution when using the FDA nomogram because it showed a propensity toward indicating oversized ICLs. [J Refract Surg. 2022;38(2):106-111.].


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares , Miopía/cirugía , Nomogramas , Estudios Retrospectivos
9.
Ophthalmol Ther ; 11(2): 785-795, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35167040

RESUMEN

INTRODUCTION: Treatment of mixed astigmatism with laser in situ keratomileusis (LASIK) is complex as the correction requires flattening the cornea in one meridian while steepening the cornea in the other meridian. The bitoric technique has become the most popular approach and has been tested across a variety of platforms. This study is the first to evaluate the results of mixed astigmatism treatment using the Allegretto WaveLight® EX500. METHODS: This study was a single-center, retrospective, noncomparative analysis of 400 eyes that underwent LASIK to correct for mixed astigmatism utilizing the EX500 excimer laser. Data on uncorrected distance visual acuity, corrected distance visual acuity, and spherical equivalent was analyzed at consecutive intervals (1, 3, 6, 9, and 12 months). Refractive measurements were used to perform a vector analysis. RESULTS: Three and 12 months postoperatively, 71% and 74% of eyes had an uncorrected distance visual acuity (UDVA) of 20/20 or better and 99% and 100% of eyes had a UDVA of 20/40 or better, respectively. The postoperative UDVA was within one line of the corrected distance visual acuity (CDVA) in 88% and 93% of eyes at 3 and 12 months, respectively. At 3 months, 78% of eyes achieved refractive astigmatism no greater than 0.50 diopters and at 12 months, 80% achieved this. The mean spherical equivalent refraction was - 0.36 ± 0.57 D at 12 months after surgery. At the 12-month follow-up, the mean refractive cylinder was reduced by 87%, from - 2.79 to - 0.37 diopters. On vector analysis, 99% of eyes had an angle of error within ± 15° from the intended target at 3 and 12 months. CONCLUSION: Treatment of mixed astigmatism using the Allegretto WaveLight® EX500 laser exceeded the industry standards of safety, efficacy, stability, and accuracy.

10.
Clin Ophthalmol ; 15: 4667-4680, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34934306

RESUMEN

PURPOSE: To assess visual outcomes over time of femtosecond laser-assisted cataract surgery compared to standard phacoemulsification cataract surgery. DESIGN: A retrospective, single-center comparative study. METHODS: Patient data including demographics, ocular biometry, pre- and postoperative visual acuity, postoperative complications, primary (uncorrected distance visual acuity over time) and secondary visual outcomes (uncorrected near visual acuity, best distance visual acuity, patient complaints, satisfaction, and postoperative surgery) were gathered and statistically analyzed. Demographic differences between patients receiving femtosecond-laser assisted cataract surgery (FLACS) versus standard phacoemulsification cataract surgery (PCS) were corrected for outcome comparison. Safety, efficacy, predictability, and stability were analyzed for each procedure and compared. RESULTS: A total of 155 eyes in PCS and 143 eyes in FLACS were analyzed at 1 week, 3 months, and 1 year using odds ratio. The odds ratio of being 20/20 or better and 20/40 or better at the specified time periods were similar and statistically insignificant at all time periods analyzed except 20/20 or better for uncorrected distance visual acuity (UDVA) at 1 year (p=0.0001) and uncorrected near visual acuity (UNVA) at 1 week (p=0.02). In both cases, the odds of being 20/20 or better favored FLACS. Mean UDVA, UNVA, and best distance visual acuity (BDVA) were all similar and statistically insignificant between the two groups. Postoperative patient complaints, safety, efficacy, predictability, and stability between the two groups showed no statistical significance. CONCLUSION: Despite the odds ratio of being 20/20 or better favoring FLACS for UDVA at 1 year and UNVA at 1 week, the mean logMAR UDVA, BDVA, and UNVA were similar and statistically insignificant between the FLACS and PCS groups at 1 week, 3 months, and 1 year. Differences in visual acuity were likely due to differences other than surgical approaches. While both FLACS and PCS are appropriate approaches to cataract surgery, one does not appear to be superior when assessing longitudinal markers for visual acuity, safety, efficacy, predictability and stability.

11.
Expert Rev Med Devices ; 18(12): 1235-1243, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34846974

RESUMEN

PURPOSE: To compare the inter-device agreement of anterior chamber depth (ACD), central corneal thickness (CCT), flat keratometry (K1), steep keratometry (K2), corneal astigmatism (ΔK), and white-to-white (WTW) measurements. METHODS: This is a retrospective study with 73 myopic patients (142 eyes). We extracted and compared anterior segment measurements (ACD, CCT, K1, K2, ΔK, and WTW) of four devices (OPD-Scan III, Pentacam HR, Lenstar LS 900, and Galilei G4), and performed pairwise agreement comparisons between them. RESULTS: Agreement analyses revealed that the most agreement occurred: in Pentacam HR and Galilei G4 for ACD measurements, in Pentacam HR and Lenstar LS 900 for CCT measurements, in OPD-Scan III and Galilei G4 for WTW measurements, in OPD-Scan III and Pentacam HR for K1 and K2 measurements, and OPD-Scan III and Galilei G4 for ΔK measurements. CONCLUSION: OPD-Scan III is interchangeable with both Galilei G4 and Lenstar LS 900 for WTW measurements. OPD-Scan III and the Pentacam-HR are interchangeable in K1, K2, and ΔK measurements. OPD-Scan III and Lenstar LS 900, and OPD-Scan III and Galilei G4 are interchangeable in K1 and ΔK measurements, respectively.


Asunto(s)
Biometría , Córnea , Córnea/diagnóstico por imagen , Diagnóstico por Imagen , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
Case Rep Ophthalmol ; 12(3): 740-748, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34720972

RESUMEN

Intrastromal corneal ring segments (ICRSs) are an effective treatment for stabilizing and normalizing corneal shape in patients with keratoconus and other corneal ectasias. Intraoperative segment perforation through the corneal endothelium into the anterior chamber (AC) is an uncommon but known complication. However, perforation into the AC postoperatively is an exceedingly rare complication with only 3 reported cases in the literature. One case was due to Descemet membrane detachment and another due to ocular trauma. In the third case, the mechanism for perforation was unclear. We present the fourth case of delayed ICRS perforation due to silent migration through the endothelium into the AC. We also present all reported cases in the literature of intraoperative and postoperative perforation into the AC.

13.
J Clin Med ; 10(17)2021 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-34501222

RESUMEN

Previous studies have demonstrated safety and efficacy using 6.0 and 6.5 mm optical zones in the WaveLight EX500 Excimer Laser System but have not evaluated if differing optical zone sizes influence refractive outcomes. This study examines visual outcomes between two study populations undergoing LASIK with either a 6.0 mm (1332 patients) or 6.5 mm (1332 patients) optical zone. Outcomes were further stratified by severity of myopia (low, moderate, and high) and astigmatism (low and high). Patients were matched by age and preoperative manifest sphere and cylinder. Postoperative measurements were then compared. The 6.5 mm group demonstrated better postoperative manifest refractive spherical equivalent (MRSE), manifest sphere, and absolute value of the difference in actual and target spherical equivalent refraction (|∆ SEQ|), within the total population, moderate myopia, and low astigmatism groups, but this did not lead to improved postoperative uncorrected distance visual acuity (UDVA) or best corrected distance visual acuity (CDVA). Though astigmatic correction and postoperative angle of error were similar between optical zone sizes, they were significantly worse with high myopia. Overall, this study demonstrates differences in visual outcomes between the 6.0 and 6.5 mm optical zone sizes that may warrant consideration; however, essentially, the results are comparable between them.

14.
Ophthalmol Ther ; 10(4): 753-776, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34417707

RESUMEN

INTRODUCTION: The incidence of ectasia following refractive surgery is unclear. This review sought to determine the worldwide rates of ectasia after photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK), and small incision lenticule extraction (SMILE) based on reports in the literature. METHODS: A systematic review was conducted according to modified Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Publications were identified by a search of eight electronic databases for relevant terms between 1984 and 2021. Patient characteristics and preoperative values including manifest refractive spherical refractive equivalent (MRSE), central corneal thickness (CCT), anterior keratometry, postoperative residual stromal bed (RSB), and percent tissue altered (PTA) were summarized. In addition, annual rates of each refractive surgery were determined, and incidence of post-refractive ectasia for each type was calculated using the number of ectatic eyes identified in the literature. RESULTS: In total, 57 eyes (70 eyes including those with preoperative risk factors for ectasia) were identified to have post-PRK ectasia, while 1453 eyes (1681 eyes including risk factors) had post-LASIK ectasia, and 11 eyes (19 eyes including risk factors) had post-SMILE ectasia. Cases of refractive surgery performed annually were estimated as 283,920 for PRK, 1,608,880 for LASIK, and 96,750 for SMILE. Reported post-refractive ectasia in eyes without preoperative identifiable risk factors occurred with the following incidences: 20 per 100,000 eyes in PRK, 90 per 100,000 eyes in LASIK, and 11 per 100,000 eyes in SMILE. The rate of ectasia in LASIK was found to be 4.5 times higher than that of PRK. CONCLUSION: Post-refractive ectasia occurs at lower rates in eyes undergoing PRK than LASIK. Although SMILE appears to have the lowest rate of ectasia, the number of cases already reported since its recent approval suggests that post-SMILE ectasia may become a concern. Considering that keratoconus is a spectrum of disease, pre-existing keratoconus may play a larger role in postoperative ectasia than previously accounted for in the literature.

15.
J Clin Med ; 10(11)2021 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-34204958

RESUMEN

Although the use of femtosecond lasers instead of mechanical devices has decreased the incidence of flap complications following laser-assisted in situ keratomileusis (LASIK), dislocations and striae still occur. Flap repositioning is an effective intervention to improve visual outcomes after acute flap complications in both microkeratome-assisted and femtosecond-assisted LASIK. This retrospective case series included patients undergoing flap repositioning secondary to acute flap dislocation and/or visually significant striae within the first two weeks following femtosecond LASIK (FS-LASIK) from 2015 to 2020 at a single institution. Preoperative, intraoperative, and postoperative de-identified data were analyzed for incidence, risk factors, and visual acuity outcomes. The incidence of flap repositioning was 0.35% in 21,536 eyes (n = 70). Indications for repositioning included acute flap dislocation (35.7%) and visually significant striae (64.3%). High myopia (OR = 3.04, p = 0.001) and patient age over 50 years (OR = 3.69, p = 0.001) were the strongest risk factors for these complications. Prior to flap repositioning, uncorrected distance visual acuity (UDVA) of 20/20 or better and 20/40 or better occurred in 19% and 57% of eyes, respectively. After repositioning, a final UDVA of 20/20 or better and 20/40 or better occurred in 78% and 98% of eyes, respectively. After repositioning, one line of UDVA was lost in two eyes (2.8%) and two lines were lost in one eye (1.4%). Risk factors for acute flap dislocation included high myopia and age over 50 years. Flap repositioning was effective in salvaging visual outcomes.

17.
Clin Ophthalmol ; 15: 2893-2906, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34262249

RESUMEN

PURPOSE: To report visual outcomes following surgical correction of myopic astigmatism with Visian Toric implantable collamer lens (ICL) (STAAR Surgical, Monrovia, CA, USA) at a single tertiary refractive center in the United States. PATIENTS AND METHODS: Toric ICL was implanted in 96 eyes (55 patients) with mean preoperative sphere of -8.98 ± 3.04 diopters (D) and cylinder of -2.67 ± 1.02 D from December 2018 to February 2021. Primary visual outcomes of efficacy, safety, stability, predictability of refractive correction, and astigmatic analysis were reported at three and twelve months postoperatively. Secondary subjective outcomes included patient-reported dry eye symptoms and glare/halos at postoperative visits. Other secondary outcomes were biometric data and postoperative vault over time. RESULTS: At three and twelve months, 75 and 46 eyes were evaluated, respectively. At twelve months, the mean manifest refraction spherical equivalent (MRSE) was -0.23 ± 0.47 D with 93% achieving within ±1.00 D of target refraction. The manifest refractive cylinder (MRC) at twelve months was -0.73 ± 0.51 D, with 86% within ±1.00 D of target. Uncorrected distance visual acuity (UDVA) was 20/20 or better in 74% of eyes at twelve months. No patients lost ≥2 lines of corrected distance visual acuity (CDVA) at twelve months. The mean angle of error was -0.9 ± 10.2° at three months and -1.6 ± 12.8° at twelve months. One patient required bilateral lens rotation, four patients underwent secondary enhancement with LASIK/PRK, and seven patients underwent postoperative limbal relaxing incisions. CONCLUSION: This initial single-site experience finds Toric ICL implantation for myopic astigmatism to be safe and effective. Patients can achieve markedly improved UDVA in a single surgery with stable vision over time and minimal adverse subjective symptoms.

18.
Clin Ophthalmol ; 15: 3051-3063, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34295144

RESUMEN

PURPOSE: To compare the visual performance of the AcrySof IQ PanOptix trifocal intraocular lens and the TECNIS Symfony extended depth-of-focus lens at near and distance visual ranges. METHODS: A total of 146 patients (221 eyes) who underwent phacoemulsification and cataract extraction and received either a PanOptix or Symfony lens from January 2019 to July 2020 were included in the study (83 PanOptix non-toric, 30 PanOptix toric, 70 Symfony non-toric, and 38 Symfony toric). Uncorrected distance (UDVA), uncorrected near (UNVA), and corrected distance (CDVA) visual acuity were assessed at one-day, one-month, and three-months postoperatively. Averages of UDVA, UNVA, and CDVA were taken to evaluate which lens was superior at near and distance visual ranges. Secondary outcome measures including glare, halo, dryness, and problems with night vision were documented at each postoperative visit. RESULTS: At one month postoperatively, the average UNVA was 0.16 ± 0.14 logMAR in the PanOptix group and 0.21 ± 0.14 logMAR in the Symfony group (P=0.007); the average UDVA for the PanOptix group was 0.09 ± 0.13 logMAR compared to the Symfony group at 0.10 ± 0.14 logMAR (P=0.67); and the average CDVA was 0.02 ± 0.05 logMAR in the PanOptix group and 0.00 ± 0.04 logMAR in the Symfony group (P=0.11). At three months postoperatively, there were no statistically significant differences in UNVA, UDVA, or CDVA between the two groups (P=0.18, 0.79, 0.68 respectively). There was no statistically significant difference in secondary outcome measures at one- and three-months (P=0.49, 0.10 respectively). CONCLUSION: The AcrySof IQ PanOptix trifocal intraocular lens appears to afford better UNVA compared to the TECNIS Symfony extended depth-of-focus intraocular lens at one-month postoperatively, though this difference was not seen at three months postoperatively. There is no statistically significant difference in UDVA and CDVA between the two groups at postoperative day one, one-month, and three-months.

19.
Clin Ophthalmol ; 15: 2963-2973, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34285462

RESUMEN

PURPOSE: This review aims to outline current practices and guidelines of corneal donation and eye banking, describes the implications of COVID-19 and emerging diseases on the corneal donor pool, and discusses future trends to improve and increase the efficiency of the processes involved in corneal donation and eye banking. SUMMARY: Corneal screening, preservation, corneal storage, and prevention of systemic disease transmission from donor to recipient have been crucial in shaping the policies of the FDA and eye banks across the world. Eye banks globally have developed varying guidelines and criteria for evaluating the viability of donor corneas. Variables such as the age of the donor, medical history, and potential disease transmission are important screening parameters. While known infectious diseases may be transmissible through the cornea, emerging infectious diseases that are not well studied may be more transmissible than other infections. In particular, coronavirus has impacted corneal transplantation as SARS-CoV-2 expression has been detected in corneal tissue and conjunctiva. In recent years, partial-thickness corneal transplantations have been introduced. Lamellar grafts and other corneal layers are now utilized for transplantation of the specific areas that are damaged.

20.
J Clin Med ; 10(14)2021 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-34300233

RESUMEN

Femtosecond (FS) lasers initially had a higher incidence of diffuse lamellar keratitis (DLK) compared with microkeratome flap creation. It has been theorized that higher-frequency lower-energy (HFLE) FS lasers would reduce the incidence of DLK. Our study sought to evaluate the incidence of newer HFLE FS lasers with pulse frequencies above 60 kHz. It was a retrospective case-control study evaluating the incidence of DLK following flap creation with one of three FS lasers (AMO iFs, WaveLight FS200, Zeiss VisuMax). Uncomplicated LASIK cases were included as the control group (14,348 eyes) and cases of DLK were recorded in the study group (637 eyes). Of the 637 cases of DLK, 76 developed stage II, 25 progressed to stage III, and only three developed stage IV DLK. The overall incidence rate of DLK was 4.3%; it has fallen with the invention of newer HFLE FS lasers and is approaching the DLK incidence rates of DLK with microkeratome.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...